1. ABB S202-C13 Automatic circuit breaker 13A pro M compact 2-pole 6kA
The S 200 series circuit breakers protect cables and wires from overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN 60947-2, and UL 1077. Their patented terminal block ensures easy and secure connection and handling through a pressure plate. For better visibility during wiring, the connection opening for wires is located above the connection opening for the phase rail. Conductor cross-sections of up to 35 mm² can be directly connected to the device via the terminal block with insulation in protection class IP20. The extensive range of accessories provides everything you need for your installation tasks. Numerous approvals make the S 200 suitable for worldwide use. Each device undergoes three intensive tests for quality and performance before delivery.

2. ABB FI/LS switch
FI/LS switches (RCBOs) provide personal and property protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure the protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC fault current component of up to 6 mA to ground. Additionally, they offer fault protection (protection against indirect contact) and additional protection (with I?n = 30 mA). They comply with the product standard IEC/EN 61009-1 (VDE 0664-20). Their patented terminal connections with Push-In technology ensure easy and secure contact and handling. The upper outgoing Push-In terminal can accommodate conductors of up to 2 x 4 mm². On the input side, the PSX phase rails can be used for cross-wiring. For power supply, conductor cross-sections of up to 10 mm² can be directly connected to the device via the screw terminal in protection class IP20. For better visibility when connecting, the connection opening of the screw terminal is located above the flexible terminal for the phase rail. Numerous approvals make the DSX203NC suitable for use in residential and commercial applications. The rated short-circuit capacity Icn is 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (Residual Current Devices) in residential buildings. The RCBO DSX203NC Type A is 3-pole protected (LS), 4-pole switching, and can be used in three-phase networks with or without a neutral conductor.

3. ABB DS203NCA-C20/0,03 FI/LS switch DS203NCA-C20/0,03 6kA, 3P+N, type A, C 20, 3
FI/LS switches (RCBOs) provide personal and property protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure the protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents, and pulsating currents with a smooth residual direct current component of up to 6 mA to ground. Additionally, they offer fault protection (protection against indirect contact), additional protection (with I?n = 30 mA), and fire protection (with I?n = 300 mA). They comply with the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application include household, commercial, and industrial uses. The extensive range of accessories provides everything you need for your installation tasks. Numerous approvals make the DS203NC suitable for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential construction and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (circuit breakers) in industrial applications. The RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching, and can be used in three-phase networks with or without a neutral conductor.

ABB DS203NCA-C20/0,03 FI/LS switch DS203NCA-C20/0,03 6kA, 3P+N, type A, C 20, 3
4. ABB AF460-30-22-70
ABB Stotz S&J motor contactor AF460-30-22-70 Manufacturer: ABB Stotz S&J. Designation: Motor contactor. Type: AF460-30-22-70. rated control supply voltage Us at AC 50 Hz: 100..250 V. Rated control supply voltage Us at AC 60 Hz: 100..250 V. Rated control supply voltage Us at DC: 100..250 V. Voltage type for actuation: AC/DC. Rated operating current Ie at AC-1, 400 V: 700 A. Rated operating current Ie at AC-3, 400 V: 460 A. Rated operating power for AC-3, 400 V: 250 kW. Rated operating power NEMA: 149.14 kW. Number of auxiliary contacts as NO contacts: 2. Number of auxiliary contacts as NC contacts: 2. Connection type main circuit: screw connection. Number of NO contacts as main contacts: 3. ABB Stotz S&J motor contactor AF460-30-22-70. contactors AF116 to AF750 from 55 to 400 kW AC-3 (400 V) represent the compact series with AC/DC control and very wide coil voltage ranges. Just 4 coils cover control voltages from 20 to 500 VDC to 24 to 500 VAC - without the need for additional cancelling elements. This means that they can be used worldwide and only in small variations. AF116 to AF370 are also available in versions that can be controlled directly from a PLC; from AF400 upwards, a PLC input is provided as standard. AF contactors switch power circuits with motors, slightly inductive or non-inductive loads. Up to 2 2-pole auxiliary switches can be mounted on the right and left side. All auxiliary break contacts are designed as mirror contacts in accordance with IEC60947-5-1 Annex L. Further accessories such as terminal covers, wiring aids and interlocking links complete the range.

5. ABB S403E-C40 S403E-C40 Miniature circuit breaker
The S 400 series circuit breakers protect cables and wires from overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They meet the construction standards DIN VDE 0641-11 or IEC/EN 60898-1, and DIN VDE 0660-101 or IEC/EN 60947-2. Their patented terminal block ensures easy and secure connection and handling via a pressure plate. Conductor cross-sections of up to 35 mm² can be connected directly to the device through the terminal block with insulation in protection class IP20. The connection is made directly via the plug socket system, and the external conductor connection can be freely chosen (L1, L2, or L3). The extensive range of accessories provides everything you need for your installation tasks. Numerous approvals make the S 400 suitable for worldwide use. Each device undergoes three intensive tests for quality and performance before delivery.

6. ABB Stotz S&J fire protection switch S-ARC1 C13
Arc Fault Detection Device (AFDD) with Miniature Circuit Breaker (MCB) according to IEC/EN 62606 (VDE 0665-10) and IEC/EN 60898-1 (VDE 0641-11) provides protection against series and parallel arc faults, overcurrent protection (overload or short circuit), surge protection (only for internal AFDD), and protection against electrically ignited fires in accordance with DIN VDE 0100-420.
Mandatory application areas according to DIN VDE 01000 are in single-phase AC systems with In = 16 A in sleeping or living areas of homes and day care facilities for children, disabled or elderly individuals, or in barrier-free apartments, as well as in rooms or locations with fire risk (with special fire hazards, fire-prone workplaces), predominantly made of combustible materials. The risk to irreplaceable goods - cultural assets of particularly high value - must also be taken into account. AFDDs are recommended in single-phase final circuits that supply electrical devices in the mentioned areas or traverse these areas.
In general, the AFDD is also recommended to enhance fire protection against electrically ignited fires.
An LED indicator helps identify the cause of the tripping. The supply can be from above or below, and cross-wiring to RCDs in the rear terminal area is possible. Accessories for the pro M compact® system can be added.
The rated short-circuit capacity according to IEC/EN 60898-1 is Icn=6kA. The AFDD+MCB S-ARC1 is single-pole protected (LS) and two-pole switching.

7. ABB S753DR-E50 sel. main LS (SHU) E-Char.,25kA,50A,3P S753DR-E50
ABB Stotz S&J Main Circuit Breaker S753DR-E50
Manufacturer: ABB Stotz S&J
Designation: Main Circuit Breaker 50A E 25kA 3P
Type: S753DR-E50
Tripping Characteristic: Other
Number of Poles: 3
Rated Current: 50 A
Rated Voltage: 400 V
Rated Insulation Voltage Ui: 690 V
Rated Short-Circuit Breaking Capacity: 25 kA
With Neutral Conductor: No
Frequency: 50 Hz
Overvoltage Category: 4
Degree of Pollution: 3
Rated Impulse Voltage Withstand: 6 kV
Mounting Type: DIN Rail
Protection Class (IP): IP20
Size (according to DIN 43880): 3
The selective main circuit breakers of the S750DR series are certified as voltage-independent selective main circuit breakers (SHU) according to DIN VDE 0641-21, designed for layman operation and suitable for the highest overvoltage category. Their application range is diverse: as a disconnection device at the meter location according to the TAB of the network operators or VDE-AR-N 4101, as well as in all low-voltage main distributions to protect distribution circuits and as a disconnection device with isolation function. Noteworthy are the special selectivity features that ensure high system availability. They are designed for mounting on a 35 mm top-hat rail according to DIN EN 60715. Devices of the S 750DR family include an integrated locking option that allows simultaneous blocking of the 3 poles of a three-phase supply. The integrated locking slider locks in the ON or OFF position and can additionally be secured with a padlock, wire seal, or cable tie. The switching state can be monitored via a mountable auxiliary switch.

8. ABB Circuit breaker
The ABB circuit breaker is a reliable and powerful device designed for use in various electrical applications. With a rated current of 250 A, this circuit breaker provides an effective solution for protecting electrical circuits and devices. It is designed as a molded case circuit breaker and features an EL trip mechanism that ensures precise control and safety. The compact design allows for easy integration into existing systems, while the robust construction ensures durability and reliability. This circuit breaker is ideal for industrial and commercial applications where high standards of electrical safety and efficiency are required.
- Circuit breaker type: Molded case circuit breaker
- Number of poles: 3
- Manufacturer commitment: SBTi
- Weight: 2323 grams.

9. ABB Circuit breaker S203MT-C16UC C16A 3 pole 10kA
The S 200 MT UC series circuit breakers protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN 60947-2, hazard level R26/HL3 according to DIN EN 45545, and requirement class 3 according to NF F 16-101/102 (I2-F3), as well as category 1 - class A/B (mounted) according to IEC 61373. Their patented terminal block ensures easy and safe connection and handling via a pressure plate. For better visibility during wiring, the connection opening for wires is located above the connection opening for the phase rail. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the terminal block with insulation in protection class IP20. The extensive range of accessories provides everything you need for your installation tasks. The S200 MT UC impresses with its high short-circuit breaking capacity and flexible use for AC and DC applications. Each device undergoes three intensive tests for quality and performance before delivery.

10. ABB F204B-63/0,5 RCCB type B 4P,63A,500mA,short-time delayed,3kA,4HP F204
F200 Type B for smooth DC residual currents and operational safety, all-current sensitive, with a short delay of 10 ms, surge current resistant up to 3 kA (5 kA in selective version). Residual current circuit breakers (RCCBs) provide protection for persons and property as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. The F200 B series RCCBs ensure protection against earth faults for sinusoidal alternating currents, pulsating currents, and smooth DC residual currents. They also provide fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA), and fire protection (with I∆n ≤ 300 mA). They comply with product standards for Type A IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) and Type B DIN EN 62423 (VDE 0664-40). Applications include household, commercial, or industrial uses. The extensive range of accessories provides everything you need for your installation tasks. Type B RCCBs are suitable for non-linear circuits that can generate residual currents with smooth DC residual currents and various (high/low) frequencies. These components are found in electronic devices such as frequency converters. Type B RCCBs have a frequency range of 0...2 kHz for detecting residual currents and offer high system availability.
Type: F204 B-63/0.5
F200 B Type Residual Current Circuit Breaker.

ABB F204B-63/0,5 RCCB type B 4P,63A,500mA,short-time delayed,3kA,4HP F204