Your data. Your choice.

If you select «Essential cookies only», we’ll use cookies and similar technologies to collect information about your device and how you use our website. We need this information to allow you to log in securely and use basic functions such as the shopping cart.

By accepting all cookies, you’re allowing us to use this data to show you personalised offers, improve our website, and display targeted adverts on our website and on other websites or apps. Some data may also be shared with third parties and advertising partners as part of this process.

Best selling Residual-current devices from Doepke

On this page you’ll find a ranking of the best Residual-current devices from Doepke. To give you a quick overview, we’ve added the most important product details. This page always stays fresh and updates automatically.

1. Doepke FI/LS combination

RCBOs combine residual current and circuit breakers in one device (RCCB/MCCB combination). They protect people from fault currents and installations from short circuits and overloads. The DRCBO 4 has a rated breaking capacity of 6 kA. In addition to a tripped indicator, it also features a labeling window. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Switches with characteristic B are the standard protection for lighting and socket circuits. Standard switches are designed for circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz.

Features: pulsating and alternating current sensitivity, mains voltage-independent tripping, compact size for all rated currents, switching position indicator, separate indication of the tripping reason, terminal blocks with a wide clamping cross-section range on both connection sides, neutral conductor on the right, labeling window, mounting type: quick fastening on mounting rail, installation position arbitrary, power supply arbitrary.

Applications: Protection of circuits in residential and commercial buildings as well as industrial plants with TN-S, TT, and TN-C-S networks. In IT networks, RCCB/MCCB switches can be used for disconnection in the event of a second earth fault. Use in systems with TN-C networks and for the protection of circuits where power electronics devices can cause smooth direct fault currents or fault currents with frequencies other than 50/60 Hz is excluded.
 

2. Doepke GmbH RCD switch DFS4 040-4/0.03A 500

The Doepke GmbH residual current circuit breaker DFS4 040-4/0.03A 500 is a highly advanced device designed for use in single-phase and three-phase networks. This circuit breaker provides reliable protection for people, animals, and electrical systems by automatically disconnecting the power supply in the event of dangerously high fault currents. With a compact design that occupies only four modular units, the DFS4 is suitable for both standard applications and special requirements. The devices are available in various versions and offer high short-circuit resistance as well as the ability to connect large conductor cross-sections via the double-decker terminals on both sides. The integrated switching position indicator and the viewing window for labeling stickers facilitate handling and maintenance. The multifunctional operating knob allows for easy operation and troubleshooting, making this residual current circuit breaker a practical choice for various electrical installations.

- Two- or four-pole design for flexible applications
- Network and auxiliary voltage-independent tripping for increased safety
- Sensitivity for alternating and pulsating direct fault currents (Type A)
- High short-circuit resistance for reliable operation
- Easy mounting on DIN rail with wide double-decker terminals.
 

3. Doepke Residual current circuit breaker

The Doepke DFS2 016-2/0.03-B SK residual current circuit breaker is a highly advanced safety device designed to immediately disconnect the power supply in the event of dangerously high fault currents. This not only protects people and animals but also electrical installations from potential damage. The switch is designed for use in single-phase networks and features a compact design that occupies only two module units. With a rated current of 16 A and a residual current of 30 mA, it is ideal for use in residential and commercial buildings. The large terminal arrangement allows for the use of conductors with larger cross-sections, making installation easier. Additionally, the switch is equipped with a special labeling software that simplifies the labeling process. Its high immunity to operational leakage and fault currents at frequencies starting from 1 kHz makes it particularly reliable in modern electrical systems.

- Two-pole residual current circuit breaker for single-phase networks
- All-current sensitive at frequencies from 0 Hz to 150 kHz
- Increased surge current and lightning resistance
- Reduced sensitivity to higher frequency responses
- Suitable for monitoring circuits with 230 V and 50 Hz.
 

4. Doepke GmbH Fi switch DFS4 040-4/0.30-B SK

The Doepke RCD DFS4 040-4/0.30-B SK is a highly advanced, all-current sensitive residual current circuit breaker specifically designed for use in electronic systems. With its 4-pole design and a rated current of 40 A, it provides reliable protection against fault currents that can occur in modern applications such as frequency converters, switch-mode power supplies, and uninterruptible power supplies. The switch meets the requirements of relevant standards, including VDE 0100 Part 530 and EN 50178, and is suitable for use in demanding environments, as it is frost-resistant down to -25 °C. With a short-circuit breaking capacity of 10 kA and an IP20 protection rating, the DFS4 ensures high safety and reliability. Installation is straightforward on a DIN rail, making it easy to integrate into various electrical systems.

- All-current sensitive residual current circuit breaker Type B
- Suitable for electronic systems with smooth DC fault currents
- Frost-resistant down to -25 °C for use in demanding environments
- Short-circuit breaking capacity of 10 kA
- Mounting on DIN rail for easy installation.
 

5. Doepke Ground fault circuit interrupter

The Doepke RCD is a highly advanced residual current device designed for use in single-phase and three-phase networks. It provides reliable protection for people, animals, and electrical systems by immediately disconnecting the power supply in the event of dangerously high fault currents. The compact design of the device allows for easy mounting on DIN rails and occupies only four modular units. With a rated current of 63 A and a rated residual current of 0.03 A, this switch is suitable for a wide range of applications. Its high immunity to operational leakage and fault currents at frequencies starting from 1 kHz enhances safety in modern electrical installations. Additionally, the switch is all-current sensitive and can detect fault currents with frequencies from 0 Hz to 150 kHz, making it particularly versatile. The integrated labeling software simplifies marking and documentation, while the large double-deck terminals are also suitable for larger conductor cross-sections.

- All-current sensitive for fault currents from 0 Hz to 150 kHz
- High immunity to operational leakage and fault currents from 1 kHz
- Compact design for easy mounting on DIN rails
- Integrated labeling software for easy marking
- Increased surge current and lightning resistance.
 

6. Doepke DFS4 040-4/0.30-HP RCD 4p 40 A 0.3 A 09136805

Residual current circuit breakers (RCCB) disconnect the power supply when dangerously high fault currents occur, thus protecting people, animals, and installations. The DFS series devices are compact four-pole residual current circuit breakers for single-phase or three-phase networks. In the standard version, they occupy only four division units. The all-current-sensitive switches detect smooth direct fault currents as well as all other fault currents according to DIN VDE 0664-400. The HP Heat Pump variant has been specifically developed for the protection of heat pumps. The protection level of the all-current-sensitive residual current circuit breaker meets all requirements of heat pump manufacturers. Additionally, the HP-optimized short-time delay ensures increased system availability. Devices in standard configuration are designed for monitoring circuits with a rated voltage of 230 V, 400 V, and a rated frequency of 50 Hz.

Features:
- All-current sensitive for fault currents with frequencies and mixed frequencies from Hz to 20 kHz
- Fire protection according to VDE 0100-420
- Full functionality with network voltages of at least 50 AC on any two active conductors
- High short-circuit resistance
- Double-deck terminals on both sides for large conductor cross-sections and rail connection
- Switching position indicator
- Multifunctional switch knob with three positions: "on," "off," "tripped"
- Neutral conductor position is arbitrary
- Mounting type: Quick fastening on mounting rail
- Installation position is arbitrary
- Preferred feeding from above

Areas of application: RCCB of the HP variant are suitable for private, commercial, and industrial installations with TN-S, TT, and TN-C-S systems where heat pumps are used.

Notes:
- Suitable for use in 50 Hz alternating current networks
- Not suitable for use on the output side of controlled electrical devices such as frequency converters.

DFS4 040-40,30-HP.
 

7. Doepke DFS4 040-4/0.03-HP RCD 4p 40 A 0.03 09134805

Doepke residual current circuit breakers (RCCB) disconnect the power supply when dangerously high fault currents occur, thus protecting people, animals, and installations. Devices from the DFS 4 series are compact four-pole residual current circuit breakers for single-phase or three-phase networks. In the standard version, they occupy only four division units. The all-current sensitive switches detect smooth direct fault currents as well as all other fault currents according to DIN VDE 0664-400. The HP (Heat Pump) variant has been specifically developed for the protection of heat pumps. The protection level of the all-current sensitive residual current circuit breaker meets all requirements of heat pump manufacturers. Additionally, the HP-optimized short-time delay ensures increased system availability. Standard version devices are designed for monitoring circuits with a rated voltage of 230 V, 400 V, and a rated frequency of 50 Hz. Features include: all-current sensitive for fault currents with frequencies and mixed frequencies from 0 Hz to 20 kHz; fire protection according to VDE 0100-420; full functionality with network voltages of at least 50 V AC on any two active conductors; high short-circuit resistance; double-deck terminals on both sides for large conductor cross-sections and rail connection; switching position indicator; multifunctional switch knob with three positions: on, off, triggered; neutral conductor position arbitrary; mounting type: quick fastening on mounting rail; installation position arbitrary; preferred feeding from above. Areas of application: RCCB of the HP variant are suitable for private, commercial, and industrial installations with TN-S, TT, and TN-C-S systems where heat pumps are used. Notes: suitable for use in 50 Hz AC networks; not suitable for use on the output side of controlled electrical devices. 

8. Doepke DRCBO 4 B16/0.03/3N-

The DRCBO 4 B16/0.03/3N-B from Doepke is a highly advanced combination RCD/MCB that integrates both residual current and overload protection in a compact device. This switch not only protects people from dangerous residual currents but also safeguards electrical installations against short circuits and overloads. With a rated breaking capacity of 6 kA and an all-current sensitive tripping characteristic, the DRCBO 4 is optimized for frequencies ranging from 0 Hz to 150 kHz. This ensures high system availability and minimizes the risk of false tripping. The switch is designed for use in lighting and socket circuits and offers a variety of features, including a switching position indicator and a labeling window that facilitate handling and installation. Its compact design and the option for quick mounting on a DIN rail make it a practical choice for various applications.

- All-current sensitive for residual currents from 0 Hz to 150 kHz
- Low sensitivity to tripping at higher frequencies to avoid false tripping
- Separate indication of the tripping reason for easy fault diagnosis
- Terminal blocks with a wide clamping cross-section range for flexible connection options
- Optimized for systems without fire protection requirements.
 

9. Doepke Residual current circuit breaker DFS4 040-4/0.03B SKR 4014712152731

The FI switch DFS4 040-4/0.03B SK from Doepke is a highly advanced residual current circuit breaker designed for use in single-phase and three-phase networks. It provides reliable protection for people, animals, and electrical systems by automatically interrupting the power supply in the event of dangerously high fault currents. With a compact design that occupies only four modular units, this switch is both space-saving and powerful. It can detect fault currents with frequencies ranging from 0 Hz to 150 kHz, making it particularly versatile. The large double-decker terminals allow for the connection of conductors with larger cross-sections, while the tripped position of the multifunction switch lever significantly facilitates troubleshooting. Additionally, the free labeling software supports easy labeling, simplifying installation and maintenance.

- All-current sensitive for fault currents from 0 Hz to 150 kHz
- High immunity to operational leakage and fault currents starting from 1 kHz
- Suitable for mounting on DIN rails
- Increased surge current and lightning resistance
- Optimized for systems without fire protection requirements.
 

10. Doepke GmbH Residual current circuit breaker all-current sensitive DFS4 080-4/0,03-B SK 4-pole 80/0,03A

The Doepke RCD DFS4 080-4/0.03-B SK is a highly advanced residual current device designed for use in single-phase and three-phase networks. With a compact design that occupies only four modular units, this device provides a reliable solution for protecting people, animals, and electrical installations from hazardous fault currents. The device is all-current sensitive and can detect fault currents with frequencies ranging from 0 Hz to 150 kHz, making it particularly versatile. Its robust construction ensures high surge current and lightning resistance, while the large double-decker terminals are suitable for larger conductor cross-sections. The tripped position of the multifunction switch lever facilitates troubleshooting, and the free labeling software aids in marking. This RCD is ideal for applications where high system availability is required.

- All-current sensitive for fault currents from 0 Hz to 150 kHz
- High immunity to operational leakage and fault currents starting from 1 kHz
- Increased surge current and lightning resistance
- Suitable for single-phase and three-phase networks
- Compatible with large conductor cross-sections due to double-decker terminals.
 

Doepke GmbH Residual current circuit breaker all-current sensitive DFS4 080-4/0,03-B SK 4-pole 80/0,03A
Residual-current device
EUR953,90

Doepke GmbH Residual current circuit breaker all-current sensitive DFS4 080-4/0,03-B SK 4-pole 80/0,03A

Product order
See all products