ANEL-Elektronik NET-PwrCtrl HUT 2 HV - High Voltage
- 8 independent sockets controlled via Ethernet / Internet using the web browser. Worldwide control.
- 8 independent sockets controlled via Ethernet / Internet using the web browser. Worldwide control.
- Screwless terminals.
- No software (except web browser) necessary to control or adjust.
- Can be used by any operating system (with a web browser).
- HTML of the pages can be changed and loaded.
- Automatic IP allocation: DHCP
- 8 inputs or outputs - freely configurable with edge detection and toggle.
- Automatic time setting from an SNTP server
- Call via hostname = http://net-control or IP
- Name/Position/Function with max. 35 characters
- Free choice of the HTTP port (0-65535), thus several devices can be accessed from the Internet.
- 'HoldOn' Button: Relay or IO is activated as long as the key is held down. Two relays or IOs can thus be used for +/- control (e.g., dimmers).
- 4 timers + 1 random timer +1 solar timer per socket with TimeLine display
- Exceptions (day/month). On selected days, all timers are skipped.
- Events can be reported by e-mail (SMTP).
- KeepAlive function: A network device can be pinged and, should it not respond, be disconnected from the power supply for an adjustable time.
- Automatic and time-delayed (0 - 18.2 h) switching on of the sockets after the start (power failure).
- Switching can also be performed as pulse (0 - 65535 sec.)
- Switching distance of the relays with simultaneous switching can be determined (0 - 255 milliseconds).
- Wake on LAN
- Sockets can be locked individually.
- User system with rights
- Logbook of the last 128 events. Power failures are registered (remains without voltage).
- Configuration can be saved and restored.
- UDP & URL interface for integration into own software
- LabView Virtual Instrument for UDP interface
- Firmware upgrade via Ethernet possible at any time (Ethernet Bootloader)
- Several devices can be controlled via a PC.
- Sturdy DIN rail housing
Delivery contents:
- NET-PwrCtrl HUT 2 HV
- Ethernet cable
- Relay: 8
- I/O: 8
- Rated voltage: 100 - 240 V~ / 50 - 60 Hz
- Power consumption: 3 W
- Max. load each relay: 16 A / 250 V~ (resistive load); 16 A / 14-; TÜV R50126372
- Terminals AK4101:
- Connection cross sections:
- Solid: 0,08 mm - 2,5 mm
- Stranded (flexible): 0,5 mm - 1,5 mm
- Stranded with Ferrule: 0,14 mm - 1,0 mm
- Ratings: VDE 250 V 17,5 A; test voltage 2,0 kV
- LAN cable: 2 m
- LAN port: 10 Base-T,10 MBit/s
- Dimensions: L 106,5 x W 95 x H 63 mm; 6 fuses wide; 35 mm DIN rail
- Temperature range: -20 °C to +60 °C
- Humidity: 10 to 90% not condensing.
- No software (except web browser) necessary to control or adjust.
- Can be used by any operating system (with a web browser).
- HTML of the pages can be changed and loaded.
- Automatic IP allocation: DHCP
- 8 inputs or outputs - freely configurable with edge detection and toggle.
- Automatic time setting from an SNTP server
- Call via hostname = http://net-control or IP
- Name/Position/Function with max. 35 characters
- Free choice of the HTTP port (0-65535), thus several devices can be accessed from the Internet.
- 'HoldOn' Button: Relay or IO is activated as long as the key is held down. Two relays or IOs can thus be used for +/- control (e.g., dimmers).
- 4 timers + 1 random timer +1 solar timer per socket with TimeLine display
- Exceptions (day/month). On selected days, all timers are skipped.
- Events can be reported by e-mail (SMTP).
- KeepAlive function: A network device can be pinged and, should it not respond, be disconnected from the power supply for an adjustable time.
- Automatic and time-delayed (0 - 18.2 h) switching on of the sockets after the start (power failure).
- Switching can also be performed as pulse (0 - 65535 sec.)
- Switching distance of the relays with simultaneous switching can be determined (0 - 255 milliseconds).
- Wake on LAN
- Sockets can be locked individually.
- User system with rights
- Logbook of the last 128 events. Power failures are registered (remains without voltage).
- Configuration can be saved and restored.
- UDP & URL interface for integration into own software
- LabView Virtual Instrument for UDP interface
- Firmware upgrade via Ethernet possible at any time (Ethernet Bootloader)
- Several devices can be controlled via a PC.
- Sturdy DIN rail housing
Delivery contents:
- NET-PwrCtrl HUT 2 HV
- Ethernet cable
- Relay: 8
- I/O: 8
- Rated voltage: 100 - 240 V~ / 50 - 60 Hz
- Power consumption: 3 W
- Max. load each relay: 16 A / 250 V~ (resistive load); 16 A / 14-; TÜV R50126372
- Terminals AK4101:
- Connection cross sections:
- Solid: 0,08 mm - 2,5 mm
- Stranded (flexible): 0,5 mm - 1,5 mm
- Stranded with Ferrule: 0,14 mm - 1,0 mm
- Ratings: VDE 250 V 17,5 A; test voltage 2,0 kV
- LAN cable: 2 m
- LAN port: 10 Base-T,10 MBit/s
- Dimensions: L 106,5 x W 95 x H 63 mm; 6 fuses wide; 35 mm DIN rail
- Temperature range: -20 °C to +60 °C
- Humidity: 10 to 90% not condensing.
Item number | 16171013 |
Manufacturer | |
Category | |
Manufacturer no. | NET-PwrCtrl HUT 2 HV |
Release date | 6/27/2021 |
Sales rank in Category Server cabinet accessories |
Length | 14.60 cm |
Width | 14.40 cm |
Height | 9.30 cm |
Weight | 359 g |
Specifications may include unverified machine translations.
Here you can see the lowest price of the day over time. Learn more
14-day cancellation right
30-day right of returnReturn policy
30-day right of returnReturn policy