Best selling Residual-current devices from JUNG
On this page you’ll find a ranking of the best Residual-current devices from JUNG. To give you a quick overview, we’ve added the most important product details. This page always stays fresh and updates automatically.
1. JUNG ARB1 TEST CD5530FIBWW
Jung Residual Current Circuit Breaker CD 5530 FIB WW
Manufacturer: Jung
Description: RCD 16A 250V 30mA
Type: CD 5530 FIB WW
Number of Poles: 2
Rated Voltage: 230 V
Rated Current: 16 A
Rated Residual Current: 0.03 A
Mounting Type: Built-in
Residual Current Type: A
Selective Type: No
Short-time Delay Type: No
Short-Circuit Strength (Icw): 3 kA
Surge Current Strength: 0.25 kA
With Locking Mechanism: No
Frequency: 60 Hz
Protection Class (IP): IP20
Installation Depth: 32 mm
Ambient Temperature During Operation: -25..40 °C
Connectable Conductor Cross-section Solid: 1.5..2.5 mm²
Additional Details:
Material: Thermoplastic according to DIN EN 61008-1 (VDE 0664-10) and DIN EN 61008-2-1 (VDE 0664-11)
Rated Residual Current: 30 mA with spring terminals for solid conductors up to 2.5 mm², not suitable for surface-mounted boxes
To be connected to 2- or 3-wire supply lines.
Installation in a 60 mm flush-mounted box (deep box recommended).
Fixed protective device with voltage-independent function.
The sockets connected to the outgoing terminals are protected in accordance with DIN VDE 0100-410.
However, the electrical installation up to the RCD is not protected!
EAN: 4011377164420.

2. JUNG ARB1 TEST LS5530FIBWW
Jung Residual Current Circuit Breaker LS 5530 FIB WW
Manufacturer: Jung
Designation: Residual Current Circuit Breaker 16A 250V 30mA
Type: LS 5530 FIB WW
Number of Poles: 2
Rated Voltage: 230 V
Rated Current: 16 A
Rated Residual Current: 0.03 A
Mounting Type: Built-in
Residual Current Type: A
Selective Type: No
Short-time Delay Type: No
Short-circuit Strength (Icw): 3 kA
Surge Current Strength: 0.25 kA
With Locking Device: No
Frequency: 60 Hz
Protection Class (IP): IP20
Installation Depth: 32 mm
Ambient Temperature during Operation: -25..40 °C
Connectable Conductor Cross-section Single-core: 1.5..2.5 mm²
Further Details:
Material: Thermoplastic according to DIN EN 61008-1 and DIN EN 61008-2-1
Rated Residual Current: 30 mA with spring terminals for rigid conductors up to 2.5 mm²
To be connected to 2- or 3-core supply lines. Not suitable for surface-mounted installations.
Installation in a 60 mm flush-mounted box (recommended deep box).
Fixed protective device with voltage-independent function.
The sockets connected to the outgoing terminals are protected in accordance with DIN VDE 0100-410.
However, the electrical installation up to the residual current circuit breaker is not protected!
EAN: 4011377164482.

3. JUNG Ground fault circuit interrupter 30mA
Jung RCD A 5530 FIB WW
Manufacturer: Jung
Description: RCD 16A 250V 30mA
Type: A 5530 FIB WW
Number of Poles: 2
Rated Voltage: 230 V
Rated Current: 16 A
Rated Residual Current: 0.03 A
Mounting Type: Built-in
Residual Current Type: A
Selective Type: No
Short-time Delay Type: No
Short-Circuit Strength (Icw): 3 kA
Surge Current Strength: 0.25 kA
With Locking Device: No
Frequency: 60 Hz
Protection Class (IP): IP20
Installation Depth: 32 mm
Ambient Temperature During Operation: -25..40 °C
Connectable Conductor Cross-Section Single-Wire: 1.5..2.5 mm²
Additional Details:
Material: Thermoplastic according to DIN EN 61008-1 (VDE 0664-10) and DIN EN 61008-2-1 (VDE 0664-11)
Rated Residual Current: 30 mA with spring terminals for rigid conductors up to 2.5 mm², not suitable for surface-mounted caps
To be connected to 2- or 3-wire supply lines.
Installation in a 60 mm flush-mounted box (recommended deep box).
Fixed protective device with voltage-independent function.
The sockets connected to the outgoing terminals are protected according to DIN VDE 0100-410.
However, the electrical installation up to the RCD is not protected!
EAN: 4011377148833.