Best selling Residual-current devices from Gewiss
On this page you’ll find a ranking of the best Residual-current devices from Gewiss. To give you a quick overview, we’ve added the most important product details. This page always stays fresh and updates automatically.
1. Gewiss GWD4532
The GWD4532 from Gewiss is a highly advanced residual current device (RCCB) designed as a voltage-independent residual current circuit breaker according to EN61008-1. This protective switch offers a reliable solution for safeguarding electrical installations against leakage currents and is suitable for retrofitting additional devices. With a rated current of 40 A and a rated residual current of 0.03 A, the GWD4532 ensures high safety and efficiency in application. The switch is designed for mounting on a DIN rail and features a compact design that easily integrates into existing systems. The protection class IP20 ensures that the switch can be used in dry indoor environments, while the high short-circuit strength of 10 kA provides additional protection. Therefore, the GWD4532 is an ideal choice for applications where safety and reliability are of utmost importance.
- Voltage-independent residual current circuit breaker (RCCB)
- Suitable for retrofitting additional devices
- Time-delayed type for increased safety
- High short-circuit strength of 10 kA
- Operating temperature range of -25 to 40 °C.

2. Gewiss GWD4537
The GWD4537 from Gewiss is a highly advanced type B residual current circuit breaker, specifically designed for use in electrical installations. This mains voltage-independent circuit breaker complies with the EN61008-1 standard and provides reliable protection against fault currents. With a rated voltage of 400 V and a rated current of 63 A, it is suitable for a wide range of applications. The GWD4537 is designed for mounting on a DIN rail and allows for the subsequent addition of supplementary devices. Its robust construction and IP20 protection rating make it ideal for indoor use, while it also offers a high short-circuit withstand strength of 10 kA. The switch is designed to operate in a temperature range of -25 to 40 °C and can be connected with multi-stranded conductors up to a cross-section of 50 mm².
- Type B fault current protection for protection against DC fault currents
- Time-delayed type for increased safety
- Locking mechanism to prevent unauthorized operation
- Suitable for the subsequent addition of supplementary devices
- High short-circuit withstand strength of 10 kA.

3. Gewiss Circuit breaker
Gewiss miniature circuit breaker GW92610
Manufacturer: Gewiss
Designation: Miniature circuit breaker C32A, 1P, 10KA, 1HP
Type: GW92610
Tripping characteristic: C
Number of poles (total): 1
Number of fused poles: 1
Rated current: 32 A
Voltage type: AC
Flush mounting: No
Switching neutral: No
Further details: Miniature circuit breaker (MCB) to EN60898-1, with time-delayed thermal overload release and electromagnetic short-circuit release. A RESTART reclosing device RM TOP, a RESTART remote operator CM, or two auxiliary devices can be mounted alternatively on the left side. With labeling window on the unit. Connection (max): 35 qmm with insulated plug-in protection. The connection screws can be fitted with a sealable cover (order accessories separately). The switch lever can be lead-sealed when switched off and on or locked with a lever lock for a padlock.

4. Gewiss FI/LS circuit breaker
Residual current circuit-breaker with integrated overcurrent protection (RCBO) in accordance with EN61009-1. Suitable for retrofitting two additional devices and/or combinations with modules for automatic restart. The switch lever can be sealed when switched off and on or locked with a lever lock (accessory sold separately) for padlock. Features an integrated residual current indicator and a hinged labelling plate. Maximum connection: 35 mm² with insulated plug-in protection. The connection screws can be fitted with a sealable cover (accessory sold separately).

5. Gewiss GEWI GW92605 Miniature circuit breaker (MCB) C-6A 10 kA 1-pole 1HP
Gewiss Circuit Breaker GW92605
Manufacturer: Gewiss
Designation: Circuit Breaker C6A 1P 10KA 1TE
Type: GW92605
Installation Depth: 72 mm
Tripping Characteristic: C
Number of Poles (total): 1
Number of Protected Poles: 1
Rated Current: 6 A
Rated Voltage: 400 V
Rated Insulation Voltage Ui: 500 V
Rated Impulse Voltage Uimp: 4 kV
Rated Breaking Capacity Icn according to EN 60898 at 230 V: 10 kA
Type of Voltage: AC
Rated Breaking Capacity Icu according to IEC 60947-2 at 230 V: 15 kA
Frequency: 50..60 Hz
Power Loss: 1.56 W
Energy Limitation Class: 3
Flush Mounting: No
Switching Neutral Conductor: No
Overvoltage Category: 3
Degree of Pollution: 3
Additional Devices Possible: Yes
Width in Division Units: 1
Protection Class (IP): IP20
Ambient Temperature During Operation: -25..60 °C
Connectable Conductor Cross-Section Multi-Stranded: 35 mm²
Connectable Conductor Cross-Section Single-Stranded: 35 mm²
Explosion-Proof: No
Gewiss Circuit Breaker GW92605: Additional Details
Miniature Circuit Breaker (MCB) according to EN60898-1, with time-delayed thermal overload release and electromagnetic short-circuit release. On the left side, a RESTART reactivation device RM TOP, a RESTART remote drive CM, or two auxiliary devices can be alternatively mounted. It features a labeling window on the device. Connection (max): 35 mm² with insulated plug-in protection. The connection screws can be equipped with a sealable cover. The switch lever can be sealed in both the ON and OFF positions or locked with a padlock using a lever lock.

Gewiss GEWI GW92605 Miniature circuit breaker (MCB) C-6A 10 kA 1-pole 1HP
6. Gewiss Ground fault circuit interrupter
Gewiss RCD GW90922
Manufacturer: Gewiss
Designation: RCD 4-p, 40A
Type: GW90922
Number of Poles: 4
Rated Voltage: 400 V
Rated Current: 40 A
Rated Residual Current: 0.03 A
Mounting Type: DIN Rail
Residual Current Type: A
Selective Type: No
Time Delay Type: No
Additional Devices Possible: No
Protection Class (IP): IP20
Width in Modular Units: 7
In the event of a trip, the ReStart function automatically resets the circuit breaker after a prior system check, restoring safe and continuous power supply. The ReStart feature is available for residual current circuit breakers and residual current protective circuit breakers. The series is complemented by the AUTOTEST devices, which perform automatic and regular self-tests without power interruption, and the PRO devices, which conduct continuous system checks after a trip.
EAN: 8011564254428.

7. Gewiss GW92068
Gewiss Circuit Breaker GW92068
Manufacturer: Gewiss
Designation: Circuit breaker 3-p, 20A, C
Type: GW92068
Installation depth: 72 mm
Tripping characteristic: C
Number of poles (total): 3
Number of protected poles: 3
Rated current: 20 A
Rated voltage: 400 V
Rated insulation voltage Ui: 500 V
Rated impulse voltage withstand Uimp: 4 kV
Rated breaking capacity Icn according to EN 60898 at 230 V: 6 kA
Voltage type: AC
Rated breaking capacity Icn according to EN 60898 at 400 V: 6 kA
Rated breaking capacity Icu according to IEC 60947-2 at 230 V: 20 kA
Rated breaking capacity Icu according to IEC 60947-2 at 400 V: 10 kA
Frequency: 50-60 Hz
Energy limitation class: 3
Flush mounting: no
Switching neutral conductor: no
Overvoltage category: 3
Pollution degree: 3
Additional devices possible: yes
Width in division units: 3
Protection class (IP): IP20
Ambient temperature during operation: -25 to 60 °C
Connectable wire cross-section multi-stranded: 35 mm²
Connectable wire cross-section single-stranded: 35 mm²
Explosion-proof: no
Gewiss Circuit Breaker GW92068: additional details
Miniature circuit breaker (MCB) according to EN60898-1, with time-delayed thermal overload release and electromagnetic short-circuit release. On the left side, a RESTART reset device RM TOP, a RESTART remote drive CM, or two auxiliary devices can alternatively be mounted. It features a labeling window on the device. Connection (max): 35 mm² with insulated plug-in protection. The connection screws can be equipped with a sealable cover. The switch lever can be sealed in both the on and off positions or locked with a padlock using a lever lock.

8. Gewiss GEWI GW92067 Miniature circuit-breaker (MCB) C-16A 6 kA 3-pole 3HP
Gewiss Circuit Breaker GW92067
Manufacturer: Gewiss
Designation: Circuit Breaker 3-p, 16A, C
Type: GW92067
Installation Depth: 72 mm
Tripping Characteristic: C
Number of Poles (total): 3
Number of Protected Poles: 3
Rated Current: 16 A
Rated Voltage: 400 V
Rated Insulation Voltage Ui: 500 V
Rated Impulse Voltage Uimp: 4 kV
Rated Breaking Capacity Icn according to EN 60898 at 230 V: 6 kA
Type of Voltage: AC
Rated Breaking Capacity Icn according to EN 60898 at 400 V: 6 kA
Rated Breaking Capacity Icu according to IEC 60947-2 at 230 V: 20 kA
Rated Breaking Capacity Icu according to IEC 60947-2 at 400 V: 10 kA
Frequency: 50..60 Hz
Energy Limitation Class: 3
Flush Mounting: no
Switching Neutral Conductor: no
Overvoltage Category: 3
Degree of Pollution: 3
Additional Devices Possible: yes
Width in Division Units: 3
Protection Class (IP): IP20
Ambient Temperature during Operation: -25..60 °C
Connectable Conductor Cross-Section Multistranded: 35 mm²
Connectable Conductor Cross-Section Solid: 35 mm²
Explosion-Proof: no
The Gewiss Circuit Breaker GW92067 is a miniature circuit breaker (MCB) according to EN60898-1, equipped with a time-delayed thermal overload trip and an electromagnetic short-circuit trip. On the left side, a RESTART reset device RM TOP, a RESTART remote drive CM, or two auxiliary devices can alternatively be mounted. It features a labeling window on the device. The maximum connection size is 35 mm² with insulated plug protection. The connection screws can be fitted with a sealable cover (accessory to be ordered separately). The switch lever can be sealed in both the ON and OFF positions or locked with a padlock using a lever lock.

Gewiss GEWI GW92067 Miniature circuit-breaker (MCB) C-16A 6 kA 3-pole 3HP
9. Gewiss Circuit breaker C1pole 15 kA
Gewiss circuit breaker GW92607
Manufacturer: Gewiss
Designation: Circuit breaker C16A, 1P, 10KA
Type: GW92607
Installation depth: 72 mm
Tripping characteristic: C
Number of poles (total): 1
Number of protected poles: 1
Rated current: 16 A
Rated voltage: 400 V
Rated insulation voltage Ui: 500 V
Rated impulse voltage withstand Uimp: 4 kV
Rated switching capacity Icn according to EN 60898 at 230 V: 10 kA
Type of voltage: AC
Rated switching capacity Icu according to IEC 60947-2 at 230 V: 15 kA
Frequency: 50-60 Hz
Power loss: 2.49 W
Energy limitation class: 3
Flush mounting: No
Switching neutral conductor: No
Overvoltage category: 3
Degree of pollution: 3
Additional devices possible: Yes
Width in division units: 1
Protection class (IP): IP20
Ambient temperature during operation: -25 to 60 °C
Connectable conductor cross-section multi-stranded: 35 mm²
Connectable conductor cross-section single-stranded: 35 mm²
Explosion protected: No
Gewiss circuit breaker GW92607: further details
Miniature circuit breaker (MCB) according to EN60898-1, with delayed thermal overload tripping device and electromagnetic short-circuit tripping device. On the left side, a RESTART reset device RM TOP, a RESTART remote drive CM, or two auxiliary devices can be alternatively mounted. With labeling window on the device. Connection (max): 35 mm² with insulated plug-in protection. The connection screws can be equipped with a sealable cover. The switch lever can be sealed in both the ON and OFF positions or locked with a padlock using a lever lock.

Gewiss Circuit breaker C1pole 15 kA
10. Gewiss GWD4534
The Gewiss FI circuit breaker GWD4534 is a highly advanced residual current protection device designed for use in electrical installations. With a four-pole configuration and a rated current of 40 A, this circuit breaker provides a reliable solution for protection against electrical fault currents. It is suitable for mounting on a DIN rail and complies with the requirements of the EN61008-1 standard. The GWD4534 is a type B residual current circuit breaker that operates independently of the mains voltage, making it suitable for demanding environments. With a rated insulation voltage of 500 V and a short-circuit strength of 10 kA, it ensures high operational safety. The circuit breaker is designed for operation in a temperature range of -25 to 40 °C and offers an IP20 protection rating, safeguarding it against dust and contact. Additionally, it allows for the subsequent installation of additional devices, increasing flexibility during installation.
- Type B residual current for mains voltage-independent protection
- Suitable for subsequent installation of additional devices
- Operating temperature range of -25 to 40 °C
- IP20 protection rating for dust and contact protection
- Short-circuit strength of 10 kA.