Schneider Electric Star delta time relay 24VDC/24-240VAC
Product details
Schneider Electric Star-Delta Timer Relay RE22R1QMU
Manufacturer: Schneider Electric
Designation: Star-Delta Timer Relay
Type: RE22R1QMU
Electrical connection type: Screw connection
Delayed response function: no
Delayed drop-out function: no
Switch-on pulse function: no
Switch-off pulse function: no
Star/Delta function: yes
Pulse shaping function: no
Flashing function starting with pause, fixed time: no
Flashing function starting with pulse, fixed time: no
Pulsing function starting with pause, variable: no
Pulsing function starting with pulse, variable: no
With plug socket: no
Remote control possible: yes
Suitable as remote control: no
Can be plugged onto contactor: no
Rated control supply voltage Us at AC 50 Hz: 24..240 V
Rated control supply voltage Us at AC 60 Hz: 24..240 V
Rated control supply voltage Us at DC: 24 V
Voltage type for actuation: AC/DC
Rated current: 8 A
Time range: 0.1..360000 s
Number of outputs, delayed, changeover: 1
Outputs, switchable delayed/undelayed: no
With semiconductor output: no
Suitable for DIN rail mounting: yes
Suitable for front mounting: no
Width: 22.5 mm
Height: 90 mm
Depth: 79.5 mm
Schneider Electric Star-Delta Timer Relay RE22R1QMU: additional details Zelio Time. Electronic timer relay for controlling automation applications in a width of 22.5 mm for mounting on a DIN rail. It features the time function for star-delta starting. The time range includes 0.1 s - 100 h, as well as 20-140 ms. A relay changeover contact at the output can handle loads of up to 8 A. Settings are made via controls on the front, which can be protected against changes under a transparent cover. LED indicators inform about the status. The supply voltage is 24 VDC/24-240 VAC. The wiring connection is made via screw terminals.
Relay type | Time relay |
input voltage | 24 V |
Output voltage | 240 V |
Electric current output | 24 A |
Output current type | AC/DC |
Item number | 9719316 |
Manufacturer | Schneider Electric |
Category | Relays |
Manufacturer No. | RE22R1QMU |
Release date | 24/9/2018 |
Relay type | Time relay |
input voltage | 24 V |
Output voltage | 240 V |
Electric current output | 24 A |
Output current type | AC/DC |
Switching function | Normally open |
Smart home | Not compatible |
Country of origin | China |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,74 |
Length | 100 mm |
Width | 22.50 mm |
Height | 90 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- 1.Metz Connect0 %
- 1.Phoenix Contact0 %
- 1.Schneider Electric0 %
- 5.Finder0,1 %
- 6.Eaton0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Shelly1 day
- ABBNot enough data
- AqaraNot enough data
- EatonNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- 7.Finder2,6 %
- 8.Aqara3 %
- 8.Schneider Electric3 %
- 10.Eaton3,5 %
- 11.Eltako3,6 %